summaryrefslogtreecommitdiffstats
path: root/po/zh_CN.po
diff options
context:
space:
mode:
authorErich Boleyn <erich@uruk.org>2009-02-06 02:11:07 +0100
committerLennart Poettering <lennart@poettering.net>2009-02-06 02:12:20 +0100
commit64926ff6b3c13d75731f19d36bc056dda1c49deb (patch)
tree577a5c72be0488e60f33dc8f4b47f65cf64df2f5 /po/zh_CN.po
parent6bb2c49057338fc88fd3846b34911878aec65b12 (diff)
RTP segfault/uninitialized resampler
Erich Boleyn <erich@uruk.org> wrote: > Using RTP for multi-room music streaming, updated to Pulse 0.9.14 from > 0.9.9, RTP reception new crashes with a segfault on all machines at > the first "Updating sample rate" log message. > > Source of the segfault appears to be null pointer for > "impl_update_rates" function in resampler routine, perhaps > uninitialized resamplers in general? A fresh look after work made the resampler initialization code pop out. The problem is in the sink connection being made from "module-rtp-recv.c", the "PA_SINK_INPUT_VARIABLE_RATE" flag should be passed into "pa_sink_input_new", but is not there. Made the change and tested it, fixes the problem. Checked and head-of- tree off of the pulseaudio.org source browsing link does not have this fix either. One-liner patch attached.
Diffstat (limited to 'po/zh_CN.po')
0 files changed, 0 insertions, 0 deletions