From 9ad567167ef6abf4598a83edabf4f6aa9642d86f Mon Sep 17 00:00:00 2001 From: Wim Taymans Date: Tue, 10 Nov 2009 13:21:55 +0100 Subject: protocol: use the right sample rate for sources Use the correct sample rate for reporting about the timing. --- src/pulsecore/protocol-native.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/src/pulsecore/protocol-native.c b/src/pulsecore/protocol-native.c index 010420ef..6e357624 100644 --- a/src/pulsecore/protocol-native.c +++ b/src/pulsecore/protocol-native.c @@ -2620,7 +2620,7 @@ static void command_get_record_latency(pa_pdispatch *pd, uint32_t command, uint3 pa_tagstruct_put_usec(reply, s->current_monitor_latency); pa_tagstruct_put_usec(reply, s->current_source_latency + - pa_bytes_to_usec(s->on_the_fly_snapshot, &s->source_output->sample_spec)); + pa_bytes_to_usec(s->on_the_fly_snapshot, &s->source_output->source->sample_spec)); pa_tagstruct_put_boolean(reply, pa_source_get_state(s->source_output->source) == PA_SOURCE_RUNNING && pa_source_output_get_state(s->source_output) == PA_SOURCE_OUTPUT_RUNNING); -- cgit